Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.392
Filtrar
1.
Clin Imaging ; 109: 110139, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38574606

RESUMO

PURPOSE: To explore the frequency of superior scapular elastofibroma dorsi in a large patient series with elastofibroma dorsi. METHODS: 136 chest CTs from January 2016 to July 2022 reporting elastofibroma dorsi were retrospectively analyzed. Three radiologists assessed the number, size, and location of elastofibroma dorsi. Continuous variables underwent two-tailed t-tests with p < 0.05. Inter-observer agreement was assessed by using Cohen's Kappa values. RESULTS: In 136 patients (mean age, 75.9 +/- 9.8 years; 117 female), 330 elastofibroma dorsi were found. Six (4.4 %) patients had single, 87 (64 %) double, 22 (16.2 %) triple and 21 (15.4 %) quadruple lesions. All single and double lesions were in the inferior scapular regions. 43 (31.6 %) patients had superior scapular lesions in addition to inferior scapular elastofibroma dorsi. Inferior scapular elastofibroma dorsi was significantly larger than superior scapular elastofibroma dorsi. The probability of a right superior lesion was significantly higher in patients with a larger right inferior lesion. Inter-observer agreement was very good for experienced radiologist (κ = 94.1) and good for other radiologists (κ = 79.4 and κ = 78). CONCLUSION: In contrast to current belief, superior scapular elastofibroma dorsi accompanying the typical inferior scapular lesions is not uncommon and can even manifest bilaterally. To the best of our knowledge, this is the first case series reporting prevalence of quadruple elastofibroma dorsi.


Assuntos
Fibroma , Neoplasias de Tecidos Moles , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Fibroma/diagnóstico por imagem , Fibroma/patologia , Escápula/diagnóstico por imagem , Escápula/patologia , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/patologia , Tórax/patologia
2.
Br J Hosp Med (Lond) ; 85(3): 1-8, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38557096

RESUMO

Fractures of the scapula are rare injuries, accounting for 3-5% of all shoulder girdle fractures. They are frequently the result of high energy trauma and often present with concurrent and life-threatening injuries to adjacent structures, leading to significant morbidity and mortality. Patients presenting with scapula fractures must receive a thorough and systematic clinical assessment as directed by national trauma guidelines. Appropriate imaging is essential in delineating fracture morphology and should at the very least include anteroposterior, anteroposterior oblique (Grashey) and axillary or scapula 'Y' view of the shoulder. Computed tomography imaging with three-dimensional reconstruction allows better delineation of the fracture morphology and helps with surgical planning. A lack of randomised controlled trials comparing the efficacy of conservative and operative management of scapula fractures has resulted in limited consensus for surgical indications. Nevertheless, most extra-articular fractures can be managed conservatively while intra-articular fractures of the glenoid frequently require surgical fixation.


Assuntos
Fraturas Ósseas , Fraturas do Ombro , Traumatismos Torácicos , Humanos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Escápula/diagnóstico por imagem , Escápula/lesões , Escápula/cirurgia , Ombro , Fixação Interna de Fraturas/métodos , Tomografia Computadorizada por Raios X
3.
J Orthop Traumatol ; 25(1): 20, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637350

RESUMO

BACKGROUND: This study aims to compare the range of motion (ROM) of reverse shoulder arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) component to regular reverse shoulder arthroplasty (RSA) lateralised by using a 42-mm glenoid component. The secondary aims are to compare patient-reported and radiographic outcomes between the two groups. MATERIALS AND METHODS: All patients with a BIO-RSA and size 38 glenosphere were retrospectively identified and matched to patients with a regular RSA and size 42 glenosphere. Matched patients were invited for a follow-up visit. ROM was assessed as well as radiographic outcomes (lateralisation, distalisation, inferior overhang, scapular notching, heterotopic bone formation, radiolucency, stress shielding, bone graft healing and viability and complications) and patient-reported outcomes (subjective shoulder value, Constant score, American Shoulder and Elbow Surgeons, activities of daily living which require internal rotation, activities of daily living which require external rotation and a visual analogue scale for pain). Outcomes were compared between the two groups. RESULTS: In total, 38 BIO-RSAs with a size 38 glenosphere were matched to 38 regular RSAs with a size 42 glenosphere. Of the 76 matched patients, 74 could be contacted and 70 (95%) were included. At the final follow-up, there were no differences between the two groups in ROM, patient-reported outcomes or radiographic outcomes (p > 0.485). CONCLUSIONS: Using a larger glenosphere is a feasible alternative to BIO-RSA for lateralising RSA, providing comparable ROM, patient-reported and radiographic results, while potentially decreasing costs, operative time and complication rates.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Atividades Cotidianas , Escápula/diagnóstico por imagem , Escápula/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
4.
Am J Sports Med ; 52(5): 1299-1307, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38488401

RESUMO

BACKGROUND: Constitutional static posterior humeral decentering (type C1 according to ABC Classification) has been recognized as a pre-osteoarthritic deformity that may lead to early-onset posterior decentering osteoarthritis at a young age. Therefore, it is important to identify possible associations of this pathologic shoulder condition to find more effective treatment options. PURPOSE: To perform a comprehensive analysis of all parameters reported to be associated with a C1 shoulder-including the osseous shoulder morphology, scapulothoracic orientation, and the muscle volume of the shoulder girdle in a single patient cohort. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: A retrospective, comparative study was conducted analyzing 17 C1 shoulders in 10 patients who underwent magnetic resonance imaging (MRI) with the complete depiction of the trunk from the base of the skull to the iliac crest, including both humeri. The mean age of the patients was 33.5 years, and all patients were men. To measure and compare the osseous shoulder morphology (glenoid version, glenoid offset, humeral torsion, anterior acromial coverage, posterior acromial coverage, posterior acromial height, and posterior acromial tilt) and scapulothoracic orientation (scapular protraction, scapular internal rotation, scapular upward rotation, scapular translation, scapular tilt, and thoracic kyphosis), these patients were matched 1 to 4 according their age, sex, and affected side with shoulder-healthy patients who had received positron emission tomography (PET)-computed tomography. To measure and compare the muscle volume of the shoulder girdle (subscapularis, infraspinatus/teres minor, supraspinatus, trapezius, deltoid, latissimus dorsi/teres major, pectoralis major, and pectoralis minor), patients were matched 1 to 2 with patients who had received PET-MRI. Patients with visible pathologies of the upper extremities were excluded. RESULTS: The C1 group had a significantly higher glenoid retroversion, increased anterior glenoid offset, reduced humeral retrotorsion, increased anterior acromial coverage, reduced posterior acromial coverage, increased posterior acromial height, and increased posterior acromial tilt compared with controls (P < .05). Decreased humeral retrotorsion showed significant correlation with higher glenoid retroversion (r = -0.742; P < .001) and higher anterior glenoid offset (r = -0.757; P < .001). Significant differences were found regarding less scapular upward rotation, less scapular tilt, and less thoracic kyphosis in the C1 group (P < .05). The muscle volume of the trapezius and deltoid was significantly higher in the C1 group (P < .05). CONCLUSION: Patients with C1 shoulders differ from healthy controls regarding osseous scapular and humeral morphology, scapulothoracic orientation, and shoulder girdle muscle distribution. These differences may be crucial in understanding the delicate balance of glenohumeral centering.


Assuntos
Instabilidade Articular , Cifose , Articulação do Ombro , Masculino , Humanos , Adulto , Feminino , Ombro/diagnóstico por imagem , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiologia , Estudos Transversais , Escápula/diagnóstico por imagem , Escápula/fisiologia , Manguito Rotador
5.
Sci Rep ; 14(1): 6500, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38499695

RESUMO

Scapular surgery has usually been performed through the posterior Judet approach. This approach allows access to the entire posterior scapular body, but causes significant soft tissue damage and detaches the deltoid muscle. To date, there has been no clinical study of a deltoid-preserving approach to access the joint for displaced postero-inferior glenoid fractures (Ideberg type II or Ib). We describe an easy and less invasive approach to the postero-inferior glenoid fossa.


Assuntos
Fraturas Ósseas , Cavidade Glenoide , Humanos , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Escápula/diagnóstico por imagem , Escápula/cirurgia , Ombro/diagnóstico por imagem , Ombro/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas
6.
J Med Case Rep ; 18(1): 94, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459542

RESUMO

INTRODUCTION: Scapular anatomical neck fractures are among the most infrequent shoulder girdle fractures. Only seven radiologically confirmed cases of scapular anatomical neck fractures have been documented in the literature to date, of which only one case underwent delayed surgery. CASE PRESENTATION: A 34-year-old male Persian patient with morbid obesity was diagnosed with a scapula anatomical neck fracture after a motor vehicle collision. The radiographic assessment of the patient indicated an increase in the scapular glenopolar angle (73.9°). Due to concurrent chest and head injuries, surgical intervention was deferred until 6 weeks following the injury. The posterolateral limited Dupont-Evrard approach was used because of the patient's extremely high body mass index. Two plates were utilized to achieve stable fixation of the glenoid neck fracture. Following a 1 year follow-up period, complete fracture union was successfully attained, resulting in a constant score of 79. CONCLUSIONS: The most accurate radiographic indicators of these fractures are a superior fracture line located laterally to the coracoid process, a small inferior spike, and an elevated glenopolar angle. The only tendon attached to the glenoid is the long head of the triceps, making these fractures unstable; therefore, surgery is required in the majority of instances. The small size of the fractured component makes stabilization more difficult. Overall, anatomical scapular neck fractures are extremely uncommon and distinguished from other scapular fractures by their unique radiological and biomechanical characteristics. This case highlights the challenges encountered when managing scapular fractures in patients with morbid obesity. The delayed surgical intervention and the choice of surgical approach tailored to the patient's specific anatomical and physiological considerations proved to be effective in achieving a favorable outcome.


Assuntos
Fraturas Ósseas , Obesidade Mórbida , Fraturas da Coluna Vertebral , Masculino , Humanos , Adulto , Estudos Retrospectivos , Fraturas Ósseas/diagnóstico por imagem , Escápula/diagnóstico por imagem , Escápula/cirurgia , Radiografia , Resultado do Tratamento , Fixação Interna de Fraturas/métodos
7.
Int Orthop ; 48(4): 1057-1063, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38302596

RESUMO

PURPOSE: The aim of the study reveals a new intuitive method for preoperatively assessing defect ratio in glenoid deficiency based on the native glenoid width and the bare spot. METHODS: A linear relationship, i.e. the rh formula, between the native glenoid width (2r) and height (h) was revealed by a cadaver cohort (n = 204). To validate the reliability of the rh formula, 280 3D-CT images of intact glenoids were recruited. To evaluate the accuracy of rh formula in estimating glenoid defect, the 65 anterior-inferior defect models were artificially established based on the 3D-CT images of intact glenoids. Moreover, a clinically common anterior-posterior (AP) method was compared with the rh formula, to verify the technical superiority of rh formula. RESULTS: The regression analysis indicated a linear relationship between the width and height of intact glenoid: 2r = 0.768 × h - 1.222 mm (R2 = 0.820, p < 0.001). An excellent reliability was found between the formula prediction and model width (ICC = 0.911, p = 0.266). An excellent agreement was found between the predicted values and model parameters (glenoid width, ICCrh = 0.967, prh = 0.778; defect ratio, prh = 0.572, ICCrh = 0.997). And, it is of higher accuracy compared to the AP method (glenoid width, ICCAP = 0.933, pAP = 0.001; defect ratio, ICCAP = 0.911, pAP = 0.033). CONCLUSION: Applying the cadaver-based formula on 3D-CT scans accurately predicts native glenoid width and redefines bare spot for preoperatively determining glenoid bone loss.


Assuntos
Doenças Ósseas Metabólicas , Cavidade Glenoide , Instabilidade Articular , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Escápula/diagnóstico por imagem , Cadáver , Cavidade Glenoide/diagnóstico por imagem
10.
Eur J Orthop Surg Traumatol ; 34(3): 1557-1562, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38280074

RESUMO

PURPOSE: Glenoid tumors are extremely rare, and reconstruction remains very challenging. The aim of this study is to present the clinical and functional outcomes, of a new glenoid reconstruction method using 3-dimensional-printed implant. METHODS: Four patients with primary glenoid tumors underwent reconstruction using 3-dimensional-printed glenoid implant linked with reverse shoulder arthroplasty. We retrospectively reviewed the clinical and functional outcome, using MSTS and DASH score, as well as complications' rate. RESULTS: Wide excision was achieved in all patients. No local recurrence or distant metastasis was diagnosed at the follow-up period. The mean MSTS score was 80.5%, and DASH score was 15.2%. According to Hendersons' classification, there were no postoperative complications. CONCLUSION: The use of 3-dimensional-printed implants, can be a very reliable solution with satisfying clinical and functional outcomes for reconstruction, in patients with musculoskeletal malignancies of the glenoid. Level of evidence IV Treatment Study.


Assuntos
Artroplastia do Ombro , Neoplasias , Articulação do Ombro , Humanos , Estudos Retrospectivos , Escápula/diagnóstico por imagem , Escápula/cirurgia , Neoplasias/etiologia , Neoplasias/patologia , Neoplasias/cirurgia , Próteses e Implantes , Impressão Tridimensional , Resultado do Tratamento , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
12.
Unfallchirurgie (Heidelb) ; 127(1): 69-78, 2024 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-38175216

RESUMO

Scapular fractures are rare injuries that require different treatment strategies. Nondisplaced fractures and the majority of scapular body fractures can be treated conservatively, while surgical treatment should be considered for displaced fractures involving the glenoid. Displaced glenoid fractures of appropriate size and intra-articular step formation should be treated surgically. Different classification systems for scapular fractures can support the treatment decision. Postoperative and posttraumatic management should include early mobilization to achieve a good functional outcome. Clear recommendations and treatment algorithms at the evidence level are not available and long-term outcomes of scapular fractures are the subject of further investigation. The results published so far show good to excellent results for surgical and conservative treatment, depending on the type of fracture. Individual patient factors should be considered when planning treatment.


Assuntos
Fraturas do Ombro , Humanos , Resultado do Tratamento , Escápula/diagnóstico por imagem
13.
J Ultrasound Med ; 43(2): 375-383, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37987527

RESUMO

OBJECTIVES: A new ultrasound-based device is proposed to non-invasively measure the orientation of the scapula in the standing position to consider this parameter for Total Shoulder Arthroplasty. The aim of this study was to assess the accuracy and reliability of this device. METHODS: Accuracy was assessed by comparing measurements made with the ultrasound device to those acquired with a three-dimensional (3D) optical localization system (Northern Digital, Canada) on a dedicated mechanical phantom. Three users performed 10 measurements on three healthy volunteers with different body mass (BMI) indices to analyze the reliability of the device by measuring the intra and interobserver variabilities. RESULTS: The mean accuracy of the device was 0.9°± 0.7 (0.01-3.03), 1.3°± 0.8 (0.03-4.55), 1.9°± 1.5 (0.05-5.76), respectively, in the axial, coronal, and sagittal planes. The interobserver and intraobserver variabilities were excellent whatever the BMI and the users experience. CONCLUSIONS: The device is accurate and reliable enough for the measurement of the scapula orientation in the standing position.


Assuntos
Articulação do Ombro , Posição Ortostática , Humanos , Reprodutibilidade dos Testes , Escápula/diagnóstico por imagem , Variações Dependentes do Observador , Canadá , Articulação do Ombro/diagnóstico por imagem , Amplitude de Movimento Articular , Fenômenos Biomecânicos
14.
J Orthop Trauma ; 38(2): e48-e54, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38031277

RESUMO

OBJECTIVES: The purpose of this study was to report patterns of scapular fractures and define them with a contemporary methodology. METHODS: . DESIGN: Retrospective study, 2015-2021. SETTING: Single, academic, Level 1 trauma center. PATIENT SELECTION CRITERIA: Consecutive patients ≥18 years, presenting with unilateral scapula fracture, with thin-slice (≤0.5-mm) bilateral computed tomography (CT) scans of the entirety of both the injured and uninjured scapulae. OUTCOME MEASURES AND COMPARISONS: Thin-slice (0.5-mm) CT scans of injured and normal scapulae were obtained to create three-dimensional (3D) virtual models. 3D modeling software (Stryker Orthopedics Modeling and Analytics, Stryker Trauma GmbH, Kiel, Germany aka SOMA) was used to create a 3D map of fracture location and frequency. Fracture zones were delineated using anatomic landmarks to characterize fracture patterns. RESULTS: Eighty-seven patients were identified with 75 (86%) extra-articular and 12 (14%) intra-articular fractures. The dominant fracture pattern emanated from the superior lateral border (zone E) to an area inferior to the spinomedial angle (zone B) and was present in 80% of extra-articular fractures. A second-most common fracture line propagated from the primary (most-common) line toward the inferior medial scapular border with a frequency of 36%. Bare zones (with 1 or no fractures present) were identified in 4 unique areas. Furthermore, intra-articular fractures were found to be heterogenous. CONCLUSIONS: The 3D fracture map created in this study confirmed that extra-articular scapular fractures occur in certain patterns with a relatively high frequency. Results provide greater insight into scapular fracture locations and may help to study prognosis of injury and improve treatment strategy including operative approaches and surgical tactics.


Assuntos
Fraturas Ósseas , Fraturas Intra-Articulares , Fraturas do Ombro , Humanos , Fraturas Intra-Articulares/cirurgia , Estudos Retrospectivos , Escápula/diagnóstico por imagem , Escápula/lesões , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Tomografia Computadorizada por Raios X
15.
Clin Rheumatol ; 43(1): 527-532, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37935986

RESUMO

INTRODUCTION: The suprascapular notch lies in the superior border of the scapula and is a passageway for the suprascapular nerve that is sensory to the shoulder joint. Suprascapular nerve block involves injection of local anaesthetic into the suprascapular notch, either ultrasound guided or blind, using the spine of scapula and/or the medial border of the acromion as surface landmarks. AIM: To investigate the anatomic variations that exist between the distance of the notch from the spine of scapula and acromion. METHOD: Ninety-two dry scapulae were measured with a digital calliper for their length of the spine, distance between the midpoint of the spine and base of the suprascapular notch and distance between the medial border of the acromion and the base of the suprascapular notch. These measurements were compared for variations in the scapular bony landmarks, the spine and the acromion to determine the site for the injection. RESULTS: Measurement reliability was assessed by intraclass correlation, Cronbach's alpha being 0.99, 0.97 and 0.91 for length of spine, distance from spine and distance from acromion respectively. The distance from the acromion had less variation in measurement (3.73 ± 0.42 cm) but a flatter distribution when compared to distance from the spine of the scapula (3.32 ± 0.39 cm). CONCLUSION: Length of the spine of the scapula appeared not to influence either distance from the acromion or distance from the spine of scapula. There is potential for greater variability in placement of nerve blocks that use acromion as the bony reference. Key Points • Dry scapular measurement using electronic Vernier callipers is accurate (0.91-0.97). • There is potential for greater variability in placement of blind nerve blocks that use acromion as the bony reference to locate the suprascapular notch.


Assuntos
Acrômio , Articulação do Ombro , Humanos , Acrômio/diagnóstico por imagem , Reprodutibilidade dos Testes , Escápula/diagnóstico por imagem , Ombro , Articulação do Ombro/diagnóstico por imagem
16.
Laryngoscope ; 134(2): 684-687, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37462362

RESUMO

OBJECTIVE: The vascular anatomy of the proximal subscapular artery has been previously classified into 2 major types depending on the presence of a common subscapular trunk. The purpose of this study was to determine the utility, reliability, and cost of routine chest imaging to identify these anatomical variations. METHODS: Data were collected retrospectively at a tertiary medical center for patients who were undergoing CT chest for various indications between October 2019 and October 2020. Two independent and blinded readers interpreted CT chest with contrast of 52 patients for a total 104 sides. RESULTS: The proximal branching pattern of the subscapular system was identified to have a common trunk in 99 (95%) sides. The remaining five sides (5%) demonstrated two arterial pedicles; with one patient exhibiting the variant anatomy bilaterally. CONCLUSION: Preoperative CT chest with contrast can accurately identify anatomic variation of the subscapular vascular system. For complex reconstruction requiring a single anastomosis in the vessel depleted neck, preoperative imaging can assure selection of a type I vascular anatomy of the proximal subscapular system. Preoperative imaging with contrasted CT has value in assessing this anatomy when planning for chimeric flaps involving circumflex scapular and thoracodorsal arteries. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:684-687, 2024.


Assuntos
Cardiopatias Congênitas , Escápula , Retalhos Cirúrgicos , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Retalhos Cirúrgicos/irrigação sanguínea , Escápula/diagnóstico por imagem , Tomografia Computadorizada por Raios X
17.
Am J Emerg Med ; 75: 196.e5-196.e7, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37923689

RESUMO

INTRODUCTION: Proper pain in acute scapular fractures can be challenging to achieve due to their anatomy and location. While the current mainstay of treatment relies on opioids, the Rhomboid Intercostal Block (RIB) has been utilized for anesthesia to effectively treat pain for scapular fractures. However, it has not yet been utilized in the emergency department (ED). CASE REPORT: In this case report, we present the first documented use of RIB to treat pain safely and effectively in a 69-year-old male with a scapula fracture following a ground-level fall in the ED. The RIB was performed under ultrasound guidance, providing precise localization and administration of the nerve block. CONCLUSION: The RIB demonstrated successful pain management in the ED. Although hopeful, further research is needed to understand limitations, potential side effects, length of pain control, and overall clinical outcomes of the RIB in the ED.


Assuntos
Fraturas das Costelas , Traumatismos Torácicos , Masculino , Humanos , Idoso , Dor/etiologia , Fraturas das Costelas/complicações , Fraturas das Costelas/diagnóstico por imagem , Fraturas das Costelas/terapia , Serviço Hospitalar de Emergência , Traumatismos Torácicos/complicações , Ultrassonografia de Intervenção , Escápula/diagnóstico por imagem , Costelas/diagnóstico por imagem
18.
Clin Biomech (Bristol, Avon) ; 111: 106157, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38103526

RESUMO

BACKGROUND: Predicting breast tissue motion using biomechanical models can provide navigational guidance during breast cancer treatment procedures. These models typically do not account for changes in posture between procedures. Difference in shoulder position can alter the shape of the pectoral muscles and breast. A greater understanding of the differences in the shoulder orientation between prone and supine could improve the accuracy of breast biomechanical models. METHODS: 19 landmarks were placed on the sternum, clavicle, scapula, and humerus of the shoulder girdle in prone and supine breast MRIs (N = 10). These landmarks were used in an optimization framework to fit subject-specific skeletal models and compare joint angles of the shoulder girdle between these positions. FINDINGS: The mean Euclidean distance between joint locations from the fitted skeletal model and the manually identified joint locations was 15.7 mm ± 2.7 mm. Significant differences were observed between prone and supine. Compared to supine position, the shoulder girdle in the prone position had the lateral end of the clavicle in more anterior translation (i.e., scapula more protracted) (P < 0.05), the scapula in more protraction (P < 0.01), the scapula in more upward rotation (associated with humerus elevation) (P < 0.05); and the humerus more elevated (P < 0.05) for both the left and right sides. INTERPRETATION: Shoulder girdle orientation was found to be different between prone and supine. These differences would affect the shape of multiple pectoral muscles, which would affect breast shape and the accuracy of biomechanical models.


Assuntos
Articulação do Ombro , Ombro , Humanos , Ombro/diagnóstico por imagem , Ombro/fisiologia , Decúbito Dorsal , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiologia , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos , Escápula/diagnóstico por imagem , Escápula/fisiologia , Rotação , Imageamento por Ressonância Magnética
19.
Clin Nucl Med ; 48(12): 1134-1135, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37934710

RESUMO

ABSTRACT: Majority of primary pediatric neuroblastomas occur in the abdomen, followed by posterior mediastinum. A 7-year-old girl presented worsening pain in the left shoulder, and a CT image of the chest revealed osseous destruction in the left scapula, suggestive of bone tumor. A biopsy was performed. Pathological result was consistent with neuroblastoma. A 123I scan with SPECT/CT images was performed, which showed only increased activity in the left scapula without any other foci of abnormal activity elsewhere.


Assuntos
Neoplasias Ósseas , Neuroblastoma , Feminino , Criança , Humanos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia , Cintilografia , Escápula/diagnóstico por imagem , Neuroblastoma/diagnóstico por imagem , Neuroblastoma/patologia
20.
BMC Musculoskelet Disord ; 24(1): 790, 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37798626

RESUMO

BACKGROUND: Glenoid bone loss is among the most important risk factors for recurrent anterior shoulder instability, and a bony reconstruction is recommended in cases of critical bone loss (> 15%). The commonly used surgical techniques, including coracoid transfer, are associated with considerable complications. The aim of this study was to assess the motion at the glenoid-bone-block interface after coracoid and spina-scapula bone-block reconstruction of the anterior glenoid. METHODS: Twelve cadaveric shoulders were tested. A 20% bone defect of the anterior glenoid was created, and the specimens were randomly assigned for glenoid augmentation using a coracoid bone block (n = 6) or a scapular spine bone block (n = 6). The glenoid-bone interface was cyclically loaded for 5000 cycles with a force of 170 N. The micromotion was tracked using an optical measurement system (GOM ARMIS) and was evaluated with the GOM Correlate Pro software. RESULTS: The most dominant motion component was medial irreversible displacement for the spina-scapula (1.87 mm; SD: 1.11 mm) and coracoid bone blocks (0.91 mm; SD: 0.29 mm) (n.s.). The most medial irreversible displacement took place during the first nine cycles. The inferior reversible displacement was significantly greater for spina-scapula bone blocks (0.28 mm, SD: 0.16 mm) compared to coracoid bone blocks (0.06 mm, SD: 0.10 mm) (p = 0.02). CONCLUSIONS: The medial irreversible displacement is the dominant motion component in a bone-block reconstruction after a critical bone loss of the anterior glenoid. The spina-scapula and coracoid bone blocks are comparable in terms of primary stability and extent of motion. Thus, spina-scapula bone blocks may serve as alternatives in bony glenoid reconstruction from a biomechanical point of view.


Assuntos
Instabilidade Articular , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Transplante Ósseo/métodos , Escápula/diagnóstico por imagem , Escápula/cirurgia , Cadáver
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...